6.1 Fick’s Law Model

In this chapter, the Fick’s Law Model will be described from the theoretical side. In 7.2 the implementation of this model into STAR-CCM+ will be presented.

6.1.1 Buoyancy Force Source

In the case of the double diffusion problem, the solutal and thermal buoyancy forces can be modelled via the Boussinesq approximation. In [1] the buoyancy parameter N is defined invoking thermal and solutal Grashof numbers GrT and GrM, respectively

𝑁 =𝐺𝑟𝑀

Based on eqn. (6.1) might be derived the density variation 𝜌′, which is then implemented into the Navier-Stokes equation [2]

𝜌 = −𝛽𝑇(𝑇 − 𝑇0) − 𝛽𝜔(𝜔 − 𝜔0) . (6.3)

In STAR-CCM+ the momentum equation in integral form is [13]

𝜕

To explain the meaning of each member of eqn. (6.4) is out of the scope of this thesis and the nomenclature might be seen in [13]. However, a special attention will be given to the body force vector due to gravity fg. Considering (6.3) fg might be specified as follows

𝑓𝑔= 𝜌𝑔[𝛽𝑇(𝑇𝑟𝑒𝑓− 𝑇) + 𝛽𝜔(𝜔𝑟𝑒𝑓− 𝜔)] , (6.5)

43 implemented into the STAR-CCM+ segregated solver as a momentum source.

6.1.2 Air-Fluid Film Interface Definition

The air-fluid film interface definition is treated similarly as in [19] and [2]. From the theory of evaporation, it is assumed a thin saturated layer of moist air above a fluid film, in which moist air and a liquid film are in thermodynamic equilibrium in this layer. The interfacial concentration of water vapour can be evaluated as follows [2]

𝜔𝑉 =𝑀𝑉 𝑀𝐴 are the molar masses of vapour and air, respectively. 𝜑 is the relative humidity, which equals unity at the air-water film interface. The saturated pressure 𝑝𝑉" [Pa] might be determined as in [2]

𝑝𝑉" = 611.85 exp (17.502 𝑇𝑠− 273.15

𝑇𝑠− 32.25) , (6.7)

where 𝑇𝑠 is the temperature of the surface of the water film. Equation (6.7) is a derived form of Tetens Equation.

Above mentioned (6.6) might be derived from expression determining the water vapour mass fraction

𝜔 = 𝑥

1 + 𝑥 , (6.8)

specific humidity is derived according to (2.9) and its general form is 𝑥 =𝑀𝑉

𝑀𝐴 𝜑𝑝𝑉"

𝑝 − 𝜑𝑝𝑉" , (6.9)

after combining (6.8) and (6.9), equation (6.6) is obtained.

In STAR-CCM+ the water vapour mass fraction determined by (6.6) is used to define a species source on the area of the fluid film to invoke the evaporative process.

44 6.1.3 Water Evaporation Rate Evaluation

STAR-CCM+ offers activation of field function Boundary Species Flux. This field function is resolved via species transport equation, which is described in details in STAR-CCM+ User Guide [13]. Diffusion term of species transport equation is dependent on diffusion flux which is related to Fick’s law. It should be also noted that the diffusion flux is evaluated with respect to laminar and turbulent diffusion. Since the main interest is in evaporation rate of water vapour relative to the surface of the water film, field function Boundary Species Flux is multiplied by water film surface 𝐴𝑆, after that, it is obtained the water evaporation rate 𝑚𝑒𝑣̇ [kg/s].

6.2 Post-processing Models

Post-processing Models used in this work are divided into two sub-approaches – Heat Transfer Analogy Based Model and Lewis Factor Analogy Based Model. However, both are based on the concept described in 5.2 and use the STAR-CCM+ as a tool to resolve the flow.

Main characteristics of Post-processing Models is that the continuum in the computational domain is assumed as single-component gas.

6.2.1 Heat Transfer Analogy Based Model

Recalling the equation (4.2) gives an apparatus to evaluate the water evaporation rate. The heat transfer coefficient hm might be evaluated according to (4.4), where the only variable unknown is the Lewis number Le.

For gas mixtures both Pr and Sc are of the order of magnitude of unity, therefore assuming 𝐿𝑒 = 1 [15] is acceptable. Such assumption simplifies the evaluation of mass transfer coefficient based on the heat transfer coefficient and from (4.4) is derived

𝑚= ℎ

𝜌𝑐𝑝 . (6.10)

The heat transfer coefficient h is resolved by STAR-CCM+, therefore the equation (4.2) to evaluate the evaporation rate becomes

𝑚̇ =𝑣 ℎ 𝜌𝐴

̅̅̅ 𝑐𝑝 𝐴𝑠 (𝜌𝐴,𝑠− 𝜌𝐴,∞) , (6.11)

where 𝜌̅̅̅ is calculated as average density of air near the fluid film and free stream air 𝐴 𝜌𝐴

̅̅̅ =𝜌𝐴,𝑆+ 𝜌𝐴,∞

2 , (6.12)

specific heat capacity at constant pressure 𝑐𝑝 as

45 𝑐𝑝= 𝜔𝐴(𝑇) 𝑐𝑝,𝐴(𝑇) + 𝜔𝑉(𝑇) 𝑐𝑝,𝑉(𝑇) , (6.13)

the density of saturated air near the surface 𝜌𝐴,𝑆 as

𝜌𝐴,𝑆 = 𝜔𝑉(𝑇𝑆) 𝜌𝐴𝑉(𝑇𝑆) , (6.14)

the density of ambient air 𝜌𝐴,∞of ambient humidity as

𝜌𝐴,∞= 𝜔𝑉(𝑇) 𝜌𝐴𝑉(𝑇) . (6.15)

In (6.14) and (6.15) is needed to evaluate the density of the moist air based on temperature 𝜌𝐴𝑉(𝑇). This might be achieved using (5.1).

6.2.2 Lewis Factor Analogy Based Model

Lewis factor 𝐿𝑒𝑓 gives an indication of the relative rates of heat and mass transfer in an evaporative process. It is equal to the ratio of the heat transfer Stanton number St and to the mass transfer Stanton number 𝑆𝑡𝑚 [20]. Heat transfer Stanton number St is defined as a modified Nusselt number and Nusselt number can be assumed as a dimensionless heat flux [10], [20]. Analogical description might be used in case of mass transfer Stanton number 𝑆𝑡𝑚 with Sherwood number Sh employed, which is referred as a dimensionless mass flux.

From the definition, Stanton numbers for heat and mass transfer are, respectively, [20]

𝑆𝑡 = 𝑁𝑢

For air-water vapour mixtures is possible to assume 𝐿𝑒𝑓 = 1 [20].

Similarly, as in 6.2.1 equation (4.2) is used to evaluate the evaporative rate. Employing (6.17) equation (4.2) becomes

𝑚𝑣̇ = ℎ

𝑐𝑝𝐿𝑒𝑓 𝐴𝑆 (𝜌𝐴,𝑠− 𝜌𝐴,∞) . (6.18)

It should be noted, that in [20] the mass transfer coefficient ℎ𝑚 is of units [𝑘𝑔

𝑚2𝑠], and this thesis adopted mass transfer coefficient ℎ𝑚 of units [𝑚𝑠], therefore convenient units conversion needs to be undertaken.

46 In the case of Lewis Factor Analogy Based Model, evaluation of parameters of equation (6.18) is analogical to determining parameters of equation (6.11). However, the evaluation of free stream temperature is different. In the case of Heat Transfer Analogy Based Model the ambient temperature is taken from the boundary condition, but for Lewis Factor Analogy based Model is used an average temperature of a control volume.

Figure 13 shows control volume, which is of width W and length L, these correspond to width and length of the fluid film area. Height h of control volume equals to ℎ =𝐻𝑥 = 0.67, this height provides most accurate results.

Figure 13 – Dimensions and location of the control volume.

47