• Nebyly nalezeny žádné výsledky

HEATING SYSTEM SECTION CTU

N/A
N/A
Protected

Academic year: 2022

Podíl "HEATING SYSTEM SECTION CTU"

Copied!
1
0
0

Načítání.... (zobrazit plný text nyní)

Fulltext

(1)

VV15 (0.70)

KORALUX RONDO COMFORT - M KRTM-122075-00M10 - 2.04 -

600

VV15 (0)

KORATHERM HORIZONTAL K11HM K11H014080-00A10 - 2.03 -

300

VV15 (0.60)

KORATHERM HORIZONTAL K11HM K11H051080-00A10 - 2.01 -

300

KORAFLEX FKX - 2.02 -

VV15 (0.60)

KORALUX RONDO COMFORT - M KRTM-122060-00M10 - 2.10 -

600

KORAFLEX FKX - 2.09 -

VV15 (2.00)

KORALUX RONDO COMFORT - M KRTM-182075-00M10 - 2.08 -

600

KORAFLEX FKX - 2.07 -

KORAFLEX FKX - 2.05 -

KORAFLEX FKX - 2.06 -

A DN 15 B B DN 15 A DN 20C C D E F F E D G G H H

DN 15 DN 15 DN 15 DN 20 DN 15

DN 15 DN 15 DN 15

DN 15

DN 15

DN 15 DN 15

DN 15 DN 15

DN 15 DN 15 DN 20 DN 15 DN 15 DN 15 DN 20 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15

VERTICAL PIPING - continues from 1NP

1. NP 0.000

KORAFLEX FVX - 1.06 - KORAFLEX FVX

- 1.08 - KORAFLEX FVX

- 1.06 - VV15 (0.60)

KORATHERM HORIZONTAL K11HM K11H022160-00A10 - 1.02 -

300

TRV 10 (1) - TRV 15 (4 Otv.)

KORATHERM HORIZONTAL K10H K10H051080-00A10 - 1.07 -

300

VV15 (0.20)

KORATHERM HORIZONTAL K11HM K11H022090-00A10 - 1.01 -

300

TRV 10 (1) - TRV 15 (0.47)

KORALUX LINEAR COMFORT KLT-122045-00-10 - 1.03 -

600

VV15 (0.20)

KORATHERM HORIZONTAL K11HM K11H022100-00A10 - 1.04 -

300

VV15 (0.30)

KORALUX RONDO COMFORT - M KRTM-090060-00M10 - 1.09 -

600

TRV 10 (8 Otv.) - TRV 15 (0,25)

KORATHERM HORIZONTAL K10H K10H059060-00A10 - 1.05 -

600

CERAPURMODUL ZBS 30/150SE-3 MA

A A B C D E F F E D G H I I H G C B

DN 32

DN 25

DN 25 DN 25 DN 25

DN 20 DN 20

DN 15 DN 15

DN 15 DN 15 DN 15 DN 15

DN 15

DN 15

DN 15 DN 15

DN 15 DN 15

DN 15

DN 25

DN 32

DN 25

DN 25 DN 25

DN 25 DN 20

DN 20 DN 15

DN 15 DN 15

DN 15 DN 15 DN 15

DN 15

DN 15

DN 15 DN 15

DN 15 DN 15

DN 15

DN 25

DN 15

VERTICAL PIPING - continues to 2NP VERTICAL PIPING - continues from 1NP

Bachelor project - Department of Microenvironmental and Building Services Engineering Name:

Attachment:

Student

Kristina Kubicova 2018-2019

Bachelor thesis supervisor doc. Ing. Michal Kabrhel, Ph.D.

Academic year

CTU

Date Scale

5/2019 M 1:50 Faculty of civil engineering

Drawing No. 6

HEATING SYSTEM SECTION

Heating and ventilation system design for villa house

NOTE:

- the pipes are located primarily in the floor

- the radiators will be connected from the wall through the corner control fittings

- all piping will be assembled in a manner, which allows the system to be vented and drained - the pipe installation will be carried out in accordance with the manufacturer's regulations

Odkazy

Související dokumenty

This will be published in the forthcoming paper in which also the methodical problems of extrapolation (including ah initio estimate of the error) will be

Terms and conditions Privacy policy.. Copyright © 2019

Let us have an £3 with the metric Q and a cartesian reference system 5^ in it. The interval ^ will be the set of all real numbers.. the mass of each of them will be 1. The position

The definition of canonical form will be determinative; the canonical form will be unique; and the definition will be so arranged thar two matrices equivalent

Once the TBMs have passed the area of Petřiny Station (this section will be provided with a temporary lining, which will be subsequently, during the excavation of the station

In the direction from the entrance portal, the tunnel waterproofi ng will be installed, the external tunnel drains will be placed and the tunnel will be backfi lled so that it

In this text (as well as in the problems), we will deal with real functions of a real variable, which means all domains and codomains of all functions will be given subsets of

will create a PostScript le lissajous.ps of the current graphics gure which can subse- quently be printed using the system print command. If filename already exists, it will