• Nebyly nalezeny žádné výsledky

Biomechanics of pelvic ring fixation techniques

N/A
N/A
Protected

Academic year: 2022

Podíl "Biomechanics of pelvic ring fixation techniques"

Copied!
2
0
0

Načítání.... (zobrazit plný text nyní)

Fulltext

(1)

C OMPUTATIONAL

CHANICS

ME

October 31 - November 2, 2018

Srní conference with international participation 34th

2018

Biomechanics of pelvic ring fixation techniques

L. Lobovsk´y

a

, J. Hartlov´a

a

, M. Sal´aˇsek

a,b

, M. Krejˇcov´a

a

, R. Tup´y

c

, T. Pavelka

b

, J. Kˇren

a

aNTIS – New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Univerzitn´ı 8, 301 00 Plzeˇn, Czech Republic

bClinic for Orthopaedics and Traumatology of Locomotive Organs, University Hospital Plzeˇn, alej Svobody 80, 304 60 Plzeˇn, Czech Republic cClinic for Radiology, University Hospital Plzeˇn, alej Svobody 80, 304 60 Plzeˇn, Czech Republic

The study focuses on development of computational tools for prediction and analysis of os- teosynthesis of pelvic ring injuries. Fractures of pelvic bones may occur after high-energy im- pact events such as car accidents or sports injuries. For surgical treatment of unstable fractures either internal or external fixators can be applied in order to support the healing bone structures.

In the following, a special attention is paid to minimally invasive internal fixation techniques for management of sacral bone injuries.

During osteosynthesis, the fractured bone parts are repositioned and the applied orthopaedic fixators prevent their relative motion. A set of ten fixation techniques is examined and a uni- lateral transforaminal sacral bone fracture (Denis type II [2]) is selected as the reference case for the study. The studied fixation techniques utilise a single or a combination of the four following orthopaedic fixators: iliosacral screw (ISS) [3], transiliac internal fixator (TIFI) [1], transiliac plate (TP) [5] or sacral bar (SB) [4].

The geometry of the computational model is developed based on CT scans of orthopaedic models of male pelvis. These solid foam models are also used in the experimental campaing that provides input data for validation of the numerical simulations. The experiments study a mechanical response of the model pelvic bones without fracture and a response of fractured bones with a selected fixation technique under physiological loading. The computational model itself is based on the finite element method. An example of the pelvic model geometry and the related computational mesh is provided in Fig. 1.

Due to the fact that each fixation technique is tested using orthopaedic plastic models, vari- ations in cadaveric samples of pelves are avoided. Thus both experimental and computational studies provide a direct comparison of the stability of selected pelvic ring fixations. All pelvic models are tested in an intact condition as well as after creation of artificial unilateral trans- foraminal fracture and application of the selected fixation technique by an orthopaedic surgeon.

In addition, the mechanical properties of the material, the orthopaedic models are made of, are determined experimentally during an extra set of tensile and compression tests.

Absolute and relative motion of the bone structures is examined, a symmetry of bone defor- mations along the median sacral crest is assessed, an evolution of the fracture line is tracked and a relative displacement of the fractured bone parts is quantified. The ratio between the stiffness of the treated pelvic structure and the stiffness of the intact model (each fixation technique is tested using an extra pelvic model) is determined. The gathered data are used to evaluate the stability of each applied fixation technique.

55

(2)

Fig. 1. The three-dimensional geometry reconstruction based on CT scans (left) and the computational mesh for the finite element analysis (right) of the fractured pelvis model with the TIFI+ISS fixation technique applied

In the experiments, a quasi-static loading is applied. The computational model reflects the experimental setup and material properties and the problem of elastostatics is solved using a finite element solver. The interaction of bone parts along the fracture line is modelled by a standard surface-to-surface contact algorithm with a finite sliding formulation and a non-zero friction. Results of the numerical simulations are compared to the experimental data and an analysis of the stability of the applied fixation techniques is provided.

Acknowledgements

This work is supported by the European Regional Development Fund-Project ”Application of Modern Technologies in Medicine and Industry” (No. CZ.02.1.01/0.0/0.0/17 048/0007280) and by the project LO1506 of the Czech Ministry of Education, Youth and Sports under the program NPU I.

References

[1] Dienstknecht, T., Berner, A., Lenich, A., Zellner, J., Mueller, M., Nerlich, M., Fuechtmeier, B., Biomechanical analysis of a transiliac internal fixator, International Orthopaedics 35 (12) (2011) 1863-1868.

[2] Fakler, J.K.M., Stahel, P.F., Lundy, D.W., Classification of Pelvic Ring Injuries. In: Fractures of the pelvis and acetabulum, W.R. Smith, B.H. Ziran, S.J. Morgan (eds.), CRC Press, Boca Raton, 2007, pp. 11-26.

[3] Gir´aldez-S´anchez M. A., L´azaro-Gonz´alvez, ´A., Mart´ınez-Reina, J., Serrano-Toledano, D., Navarro-Robles, A., Cano-Luis, P., Fragkakis, E.M., Giannoudis, P.V., Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis, Injury 46 (2) (2015) 327-332.

[4] Gorczyca, J.T., Varga, E., Woodside, T., Hearn, T., Powell, J., Tile, M., The strength of iliosacral lag screws and transiliac bars in the fixation of vertically unstable pelvic injuries with sacral frac- tures, Injury 27 (8) (1996) 561-564.

[5] Suzuki, T., Hak, D.J., Ziran, B.H., Adams, S.A., Stahel, P.F., Morgan, S.J., Smith, W.R., Outcome and complications of posterior transiliac plating for vertically unstable sacral fractures, Injury 40 (4) (2009) 405-409.

56

Odkazy

Související dokumenty

Výše uvedené výzkumy podkopaly předpoklady, na nichž je založen ten směr výzkumu stranických efektů na volbu strany, který využívá logiku kauzál- ního trychtýře a

Doblar´e, “A three- dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint,” Journal of Biomechanics, vol.. Barry,

-Pelvis position: the pelvis is shifted to the right side and is higher on the right side, also there is a slight left rotation of the pelvis, right side is more forward

Three-dimensional numerical method, which combines the 2D finite element method in a plane perpendicular to the fault with application of the Fourier transform in the direction

c) In order to maintain the operation of the faculty, the employees of the study department will be allowed to enter the premises every Monday and Thursday and to stay only for

Studijní program: Kvantitativní metody v ekonomice Studijní obor: Ekonometrie a operační výzkum Akademický rok: 2020/2021.. Název práce: Spatial framework for real estate

2) Autor na tématu pracuje dlouhodobě a dle mého soudu je to na práci také vidět. Již při diskusi o zadání práce měl autor připraveny dílčí výsledky, z nichž bylo

The fifth analysis studied this assumption, and the results showed that the majority of participants who think start-up is the solution to unemployment did not choose